WARNING:
JavaScript is turned OFF. None of the links on this concept map will
work until it is reactivated.
If you need help turning JavaScript On, click here.
This Concept Map, created with IHMC CmapTools, has information related to: Active thermal control of power electronic modules, Regions in Fuzzy control classified based on change in measure junction temperature, based on change in measure junction temperature sets Power cycling Low, regulate temperature of the module ???? controlling switching frequency, Normal operation description current limit: 2x nominal current switching frequency: nominal, shutdown operation shutdown the module when fsw= minimum I =minimum and T C, Over-temperature description temperature exceeds nomial temperature limit(110C), Power cycling High description ΔTj_fast is above its limits. Imin =acceptable performance limit of drive, regulate temperature of the module ???? output current, based on change in measure junction temperature sets shutdown, power cycling failure !! reason accumulated fatigue damage from physicalw stress cycles over the lifetime of the module, power module thermal failure reason power cycling failure !!, based on change in measure junction temperature sets Over-temperature, based on change in measure junction temperature sets Normal operation, based on change in measure junction temperature sets Power cycling High, power module thermal failure reason overtemperature, regulate temperature of the module ???? adhustable 1. turn-on 2. turn-off control rates for current and voltage